Static Application

FE

PROFINET-ETHERCAT 1000V cat.5E

Applicative Features

Minimum Bending radius
Cross Section Cross section max Dynamic Installation Static installation
0.22 0.34 6.0xØ

Approvals

Certification image not found

AWM STYLE 2570 80°C 1000V

Certification image not found

AWM I/II A/B 80°C 1000V

Certification image not found

2014/35/CEE

Certification image not found

2014/30/EU

Certification image not found

2011/65/UE

Certification image not found

1907/2006

Technical data

image
Installation -5°C +80°C
static -30°C +80°C
image
Nominal voltage 1000V (UL)
Max operating voltage 100V EN 50288-2-1 / 2-2
image
Test Voltage 1000V (EU), 3000V (UL)
Test Voltage Reference acc.to IEC 61156-5, EN 50288-2-1 / 2-2 (EU)
image
Insulation resistance ≥500 Mohm/Km
image
Nominal impedance

100±15% ohm

Attenuation
22 AWG
MHz dB/100m
1.00 MHz 1.9
4.00 MHz 3.9
10.00 MHz 6.2
16.00 MHz 7.8
20.00 MHz 8.8
31.00 MHz 10,7
62.50 MHz 14.8
100.00 MHz 18.9
155.52 MHz
200.00 MHz
250.00 MHz

Construction features

Group 1
Conductor

CL2 Flexible.

Tinned copper

Insulation

Polyethylene compound (PE)

Insulation Color

Clockwise sequence: White, Yellow, Blue, Orange

Pairs in star quad position.

 

Overall stranding
separationLayer Tape

PET - Polyester.

sheath Sheath intermediate

TPE

separationLayer Shilded Tape

Mylar inside - Alluminium outside

screen Shield braid

Tinned copper

85 % ± 5 %
Sheath

PVC compound.

Sheath Colour

Green

, RAL: 6018, desina: no

Products features

image

Fire performance

FT1(CSA); IEC 60332-1-2(EU)

image

Oil performance

VDE 0473-811-404, IEC 60811-404, (EU) CEI EN 50363-10-2, 1581 (UL)

image

Uv performance

according to ISO 4892-2, EN 50289-4-17, ASTM-D-2565-16

teco code Oem ref. Formation Capacitance [nF/Km] cut rolls [M] drums [M] Ext Ø [mm] Weight [kg/km]
37488 SIEMENS 6XV1870-2BU10

(1x4xAWG22/7)Q-R-SN-ST

0.05 100 500 6.5 63