Static Application

UE

PROFIBUS

Applicative Features

Minimum Bending radius
Cross Section Cross section max Dynamic Installation Static installation
0.34 0.34 10.0xØ

Approvals

Certification image not found

AWM STYLE 2571 80°C 300V

Certification image not found

AWM I/II A/B 80°C 300V

Certification image not found

2014/35/CEE

Certification image not found

2014/30/EU

Certification image not found

2011/65/UE

Certification image not found

1907/2006

Technical data

image
Installation -5°C +80°C
static -30°C +80°C
image
Nominal voltage 300V
image
Test Voltage 2000V
image
Insulation resistance 5 Gohm/km
image
Nominal impedance

150±10% ohm

 

 

Attenuation
22 AWG
MHz dB/100m
1.00 MHz
4.00 MHz 2.2
10.00 MHz
16.00 MHz 4
20.00 MHz
31.00 MHz
62.50 MHz
100.00 MHz
155.52 MHz
200.00 MHz
250.00 MHz

Construction features

Group 1
Conductor

Solid

Bare copper.

Insulation

Expanded polyethylene (PEE)

Insulation Color

green red

Overall Stranding
filler Filler

Polypropylene

separationLayer Tape polyester

PET - Polyester.

screen Shield tape

Mylar inside - Alluminium outside

100 % ± 5 %
screen Shield braid

Tinned copper

65 % ± 5 %
separationLayer Tape

Non-woven tape

Sheath

PVC compound.

Sheath Colour

Violet

, RAL: 4001, desina: yes

Products features

image

Fire performance

VW-1(UL); FT1(CSA); IEC 60332-1-2(EU)
image

Oil performance

1581(UL); IEC 60811-404(EU); CEI EN 50363-4-1(EU); ICEA S-82-552; IRM902

teco code Oem ref. Formation Capacitance [nF/Km] cut rolls [M] drums [M] Ext Ø [mm] Weight [kg/km]
11337 SIEMENS 6XV1830-0EH10

(1x2xAWG22/1)SN/ST

30 500 8 65