immagine

Dynamic Application

PMXX®️ PLUS

SERVO

Applicative Features

image
Up to 5 million
Guaranteed Cycles
50,0 m/s2
Acceleration
25,0 m
Cable length
300,0 m/min
Travel speed
Minimum Bending radius
Cross Section Cross section max Dynamic Installation Static installation
0.50 16.00 6xØ 3xØ
25.00 95.00 10xØ 5xØ

Approvals

Certification image not found

AWM STYLE 21209 90°C 1000V

Certification image not found

AWM I/II A/B 90°C 1000V

Certification image not found

2014/35/CEE

Certification image not found

2014/30/EU

Certification image not found

2011/65/UE

Certification image not found

1907/2006

Certification image not found

IEC 60754-1

EN 50267-1

Technical data

image
storage

-50°C +80°C

dynamic

-30°C +90°C

static

-40°C +90°C

image
Nominal voltage

1000 V (UL/CSA) uo/U 0,6/1 kV (VDE)

image
Test Voltage

4,0 kV

Test Voltage Reference

EN 50395 part 6-7

UL/1581

image
Insulation resistance

≥1 Gohm/Km(20°C)

≥10 Mohm/Km(90°C)

Construction features

Power conductors

Conductor

CL6 Extra-flexible.

Bare copper.

Insulation

Polypropylene compound (PP)

Insulation Color

Black core with white printing ( U/L1/C/L+

V/L2

W/L3/D/L-) +&nbsp

Green-Yellow.

separationLayer

Inner tape

Polyester transparent tape or non-woven tape

Overall Stranding Servo

filler

Filler

Polypropylene

separationLayer

Tape

Non-woven tape

screen

Screen

Tinned copper

85 % ± 5 %

separationLayer

Tape

Non-woven tape

Sheath

Polyurethane&nbsp

compound (TMPU)

Sheath Colour Orange, RAL: 2003, desina: yes

Products features

image

Fire performance

Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2

&nbsp

DIN EN 60332-1-2

IEC 60332-1-2

UL 1581 sec.1061 Cable flame

UL VW-1

CSA FT1

image

Oil performance

VDE 0207-363-10-2

IEC 60811-404 (EU)

CEI EN 50363-10-2

1581 (UL)

image

Uv performance

according to ISO 4892-2

EN 50289-4-17

ASTM-D-2565-16

EN 50618

image

Water performance

UL 1581

IEC 60811-1-3

EN 50396 (Hydrolyses Resistance)

image

cold Performance

EN60811-1-4

image

Abrasion performance

ASTM D 4060

image

Mud performance

Nek TS 606

&nbsp

IEC 60092-360 Annex C+D

image

Microbe performance

VDE 0282/10

image

Hozone performance

EN 50396 Met. B

teco code Oem ref. Formation cut rolls [M] drums [M] Ext Ø [mm] Weight [kg/km]

46158

(3G1,50)ST

(3GAWG16)ST

100

500

8.2

110

46159

(3G2,50)ST

(3GAWG14)ST

500

9.6

170

46160

(4G1,00)ST

(4GAWG18)ST

100

500

8.2

100

46161

SIEMENS

6FX8008-1BB11

(4G1,50)ST

(4GAWG16)ST

100

500

9

140

46162

SIEMENS

6FX8008-1BB21

(4G2,50)ST

(4GAWG14)ST

500

10.6

198

46163

SIEMENS

6FX8008-1BB31

(4G4,00)ST

(4GAWG12)ST

500/100

12.3

265

46164

SIEMENS

6FX8008-1BB41

(4G6,00)ST

(4GAWG10)ST

100

14.5

400

46165

SIEMENS

6FX8008-1BB51

(4G10,00)ST

(4GAWG08)ST

17.5

590

46166

SIEMENS

6FX8008-1BB61

(4G16,00)ST

(4GAWG06)ST

21.6

1010

46167

SIEMENS

6FX8008-1BB25

(4G25,00)ST

(4GAWG04)ST

25

1480

46168

SIEMENS

6FX8008-1BB35

(4G35,00)ST

(4GAWG02)ST

29.4

1950

46169

SIEMENS

6FX8008-1BB50

(4G50,00)ST

(4GAWG01)ST

34

2850

46170

SIEMENS

6FX5008-1BB70

(4G70,00)ST

(4GAWG2/0)ST

39.9

3965

46171

SIEMENS

6FX8008-1BB95

(4G95,00)ST

(4GAWG3/0)ST

47.5

5200