teco code | Formation | cut | rolls [M] | drums [M] | Ext Ø [mm] | Weight [kg/km] |
---|---|---|---|---|---|---|
12746 | (1x2xAWG22/44)ST/SN
|
100 | 500 | 8 | 85 | |
Cross Section | Cross section max | Dynamic Installation | Static installation |
---|---|---|---|
0.34 | 0.34 | 7.5XØ | 6XØ |
AWM STYLE 20236 80°C 30V
AWM I-II A-B 80°C 30V
2014/30/EU
2011/65/UE
1907/2006
IEC 60754-1
Signal | |
---|---|
Conductor | Bare copper. |
Insulation | Expanded polyethylene (PEE) |
Insulation Color | green red |
Overall Stranding | |
---|---|
filler |
Filler
Polypropylene |
separationLayer |
Tape
PET - Polyester. |
screen |
Shield braid
Tinned copper 85 % ± 5 % |
screen |
Shield tape
Alluminium inside/non-woven outside 100 % ± 5 % |
screen |
Shield tape
Alluminium inside/non-woven outside 100 % ± 5 % |
Sheath | Polyurethane compound (TMPU) |
Sheath Colour | Violet , RAL: 4001, desina: yes |
Fire performance
FT1(CSA); IEC 60332-1-2(EU)Oil performance
CEI EN 50363-10-2(EU); IRM 902Uv performance
UV RESISTANT
teco code | Formation | cut | rolls [M] | drums [M] | Ext Ø [mm] | Weight [kg/km] |
---|---|---|---|---|---|---|
12746 | (1x2xAWG22/44)ST/SN
|
100 | 500 | 8 | 85 | |